Wave 2
Epics
- VLA Calibration Improvement: Improvements to the flagging heuristics for system and RFI Issues.
- RFI heuristics for VLA PI pipeline will be modified - moving toward VLASS or VLASS-derived
- bad deformatter flagging should gracefully recover from bad deformatter on refant
- Heuristic changes for bad deformatter identification
- proper multi-band support
- allow different min/max solints per band
- allow different bandpass calibrators per band
- API plot should appear in weblog
- gaintable flagging of final gaintables based on statistics (do within final cals?)
- heuristics need to be defined
- Fluxboot 2 display refinements (PIPE-319, PIPE-426)
- Fluxboot fitorder determined when different gain calibrators used for different bands
- Antenna pointing solutions in weblog
- observing log in weblog
- flagging summary per stage (SRDP-411)
- AQUA Report needs to be finished (SRDP-194, CASR-263, CASR-358)
- VLA Spectral Line Calibration: Modifications to the system to support Spectral Line science with the VLA.
- per-baseband delay capability should be implemented
- ability to use spw-mapping per baseband for final gain calibration in low S/N regime (mixed spw setups)
- pipeline should use fluxboot2 results to determine if gain calibration on individual spws will have too low S/N
- switched power weights (CASR-476)
- mstransform hanning smooth pass through (CASR-357)
- SPW intents and processing options need to be passed from RCT/OPT to pipeline
- SDM option
- PPR option
- Intents : Spectral Line or Continuum
- Processing Options: Hanning smooth, RFI Flagging, Statwt
- VLA Imaging Pipeline: Initial version of VLA Imaging pipeline targeting Ku-band and above
- establish imaging benchmark suite using existing SRDP-QA'd SBs
- continuum-only
- Use nsigma threshhold
- X-band and higher frequency
- ALMA User-Defined Imaging: Additional options in the pipeline and interface
- Pipeline
- Selectable resolution
- higher resolution (robust=0.0 for mosaics, robust=-0.5 single pointing)
- possibly useful for ACA and 12m
- max sensitivity (12 m only)
- max sensitivity + larger scale (12 m only)
- robust=2
- tapering of some percentile of uv distances
- Self-calibration
- requirements and suggested implementation under discussion
- Add additional call to MFS imaging on continuum-subtraced data
- Characterization of continuum subtraction quality/reliability
- must not overwrite mfs images of continuum generated earlier in PL recipe
- Interface
- rest frequencies for commonly used transitions selectable (interface with splatalogue)
- support the multiple resolution modes
- multiple sources per request
- multiple cube requests
- Scrape hifa_imageprecheck weblog output to beam sizes for different resolution selections
- Enable user to manually edit their continuum regions
- Use cont.dat from archive as starting point (if available)
- show plot of continuum regions
- Ability to Pan and Zoom in plot
- when possible use CARTA to extract spectra from archive datacubes within masks
- plot spectra in window
- regions defined as start and end in LSRK frequency
- organize in rows
- add/delete rows
- expand manually with mouse
- Enable user to request delivery of calibrated MS with imaging request
- Infrastructure
- Split workflow for Restore and Imaging
- Enables Restore in same CASA version as reduction (e.g., 5.1.1) and newest for imaging (5.6.1)
- Add option to deliver calibrated MS in addition to images to user
- Improved Download Support: Cutouts for images and data selection for MS downloads
- Archive restore workflows should use XML template recipes for VLA and ALMA delivery
- templates provided in CASA 5.6.1/2
- enable intent selection, target selection, frequency averaging, and time averaging
- batch request capability
- upload formatted catalog, obtain cutouts against selected image collections (e.g., ALMA, VLASS)
- Metadata Improvement: Improved meta-data for products in the archive.
- Migrate to a refreshed archive-new interface
- Ability add/hide presentation of some metadata associated with project/observation/image
- Thumbnails for archived image products
- Clickable to obtain large thumbnail
- Determine thumbnail generation mode
- crawl and process
- scrape weblogs
- Must be proprietary-state aware
- QA State for different telescopes
- ALMA
- QA2 per MOUS
- QA0 per EB
- SRDP Imaging
- VLA/SRDP QA
- Weblog from Calibrations linked and viewable through archive
- VLA
- ALMA Calibration
- ALMA Imaging (If separate from Calibration run)
- ALMA SRDP Imaging
- Proprietary state properly reported
- VLA Receiver Band Metadata correction
- Fix older EVLA data (listed as subband...)
- Angular resolution
- Displayed per MOUS for ALMA
- Tabulated approximately per VLA band/configuration
- Conform to standard results table from System Requirements document
- Search operates properly on images using their field of view
- Search operates properly for mosaic observations (EBs and MOUSes)
- Results should be returned if search position is within mosaic
- CARTA- Archive Integration: Integration of the CARTA viewer with the Archive.
- Support starting CARTA backend (require to be logged-in) and user views through new web browser tab
- User should be able to select an image product and open it in CARTA
- User should see a progress bar so they know what is happening
- important for large cubes that are not available within seconds
- Ability to open second image from archive within CARTA and overlay
- Regions support is required
- region information should be available to archive interface for cutout or search functionality
- Ability to upload their own image
- Overlay catalogs (available in archive or external catalog available in CARTA)
- those in archive (e.g., NVSS, VLASS, etc)
- external catalogs available in CARTA (e.g., 2MASS, IRAS, GAIA, FIRST, NVSS, IRAS)
- external image servers available to CARTA (e.g., DSS, SDSS, 2MASS, IRAS, WISE)
- Upload user's catalog
- Enable CARTA to be used behind the scenes to extract data from Cubes (e.g., spectra) for use in interface
- Enable user to download fits or other image format from CARTA view
- Catalog Support: Support for searchable scientific catalogs in the Archive
- Catalogs should be searchable from a subset of search filters
- Return results able to be used as query for project/observation/image searches
- Ability to hide columns
- Interface for projects to upload catalogs for ingestion
- Image Ingestion: If not already complete the ingestion and service of VLASS and ALMA images.
- ALMA
- ALMA cubes and continuum images associated with each MOUS need to be ingested
- ALMA image products must be displayed to users and downloadable
- Thumbnails should be present for ALMA image products
- Viewable in a CARTA session
- VLASS
- VLASS QL images from the entire first epoch must be ingested
- VLASS images must be displayed and downloadable
- VLASS images require thumbnails and high-resolution png images
- Viewable in CARTA session
- VLA Images
- When VLA imaging pipeline comes on line products must be ingested
- Image products have same requirements as ALMA image products
- Ancillary products for all imaging products should be made available for download
- Large Project Support: Support for the ingest and serving of products from Large projects as collections.
- VLA Sky Survey
- Epochs 1.1 and 1.2 images ingested and served
- proper position search within the images and SDMs for VLASS
- Projects should be viewable as a 'collection' to see only the data from that project.
- project specific metadata should be searchable
- Interface to support upload and ingestion of large project data
- Observatory Calibrator Database: Development of a centralized calibrator database for the VLA.
- Calibrator Flux densities
- Per VLA Band
- Central frequency
- bandwidth
- spectral index and curvature
- Date
- Calibrator models
- Time-dependent models
- Polarization models
- models with spatial and spectral information
- Antenna position database
- Performance Improvement: Efforts to make the system more responsive and decrease product latency.
- Optimized imaging
- Multiple sources per MOUS grouped into single request
- Multiple cubes specified per source(s) grouped into single request
- Reduce restore load if user comes back to specifc MOUS several times for different jobs
- Skip continuum finding step when possible
- Data from current ALMA cycle should use the archived cont.dat when possible
- Older data should always make use of current continuum finding routines
- Must check that source(s)/spw selected for imaging has continuum defined in cont.dat
- Data that are size mitigated might not have a region defined for all sources/spws
- Restore
- Reduce latency for popular data sets
- Restore datasets with same CASA version as calibrated with
Relevant Documents
Useful Links