Motivated by SSA-6514 and SSA-6616 (see also PIPE-749), this page lists the requirements for what should be delivered for basic and calibrated measurement sets in the SRAO workflow.
Basic measurement sets (ALMA and VLA)
Products made available to the users should include, and be limited to:
- Untarred, uncompressed measurement set with online flags applied if the "apply online flags" dialog box is checked.
- Untarred, uncompressed weblog for the MS creation.
- PPR.xml, *casa_pipescript.py and *casa_commands.log for the MS creation
- *auxproducts.tgz
If a tar file is requested, all the above shall be tarred and compressed and delivered as a single tar.gz file. Files that are only used in the NRAO workflows (the manifest and aqua report) shall not be delivered to the user.
Calibrated measurement sets (ALMA and VLA)
Products made available to the users should include, and be limited to:
- Untarred, uncompressed measurement set(s) as output from the pipeline, containing both data and corrected columns and all sources including calibrators calibrated (needed for polarization calibration workflows).
- Untarred, uncompressed weblog for the calibration, clearly distinguished from the restore weblog (e.g. called "weblog_calibration").
- Untarred, uncompressed weblog for the restore, clearly distinguished from the calibration weblog (e.g. called "weblog_restore").
- PPR.xml, *calapply.txt, *casa_piperestorescript.py files for the restore.
- *casa_pipescript.py, *casa_commands.log for calibration (PPR too?).
- flux.csv (if used/supplied)
- *flagtemplate.txt, *flagtsystemplate.txt (if used/supplied).
- *caltables.tgz
If a tar file is requested, all the above shall be tarred and compressed and delivered as a single tar.gz file. Files that are only used in the NRAO workflows (the manifest and aqua report) shall not be delivered to the user.