Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

C:A0C0 and C:A1C1, amp solution bumps, possibly as early as Jan begins near 2022-01-07, persists through B , > BnA , > A
uncertain if same cause in 3bit and 8bit. examples of both are here> D.

Data sets:
/lustre/aoc/projects/srdp/problem_data/ea01_AC/
8bit:
3bit:
Image Removed
below, black is ea01 (brown is the typical ea17 issue)Image Removed

--------------------------
Still present after move to D

22A-172.sb41900438.eb42462902.59788.088626770834

Image Added

--------------------------
Clear example just before A > D move time, this one calibrates ok

Job: 22A-115_2022_07_04_T09_01_26.871
SDM: 22A-115.sb41273726.eb41917124.59764.32381357639


Image Added

--------------------------
UPDATE 2022-06-22

Issue has become more noticeable in corrected amps. Example:
22A-211.sb41331182.eb41830205.59730.99877748842

ea01 is the black stuff at the low end


Image Added

------------------------

older examples, amp solutions from finalcals

8bit:
Image Added

3bit:
Image Added