- Why does iperf show 10Gb/s between na-arc-5 and na-arc-[1,2,4]? How is this possible if the default interface on the respective VM Hosts is 1Gb/s?
- ANSWER: The vnets for the VM guests are tied to the 10Gb/s NICs on the VM hosts not the 1Gb/s NICs.
- Why do natest-arc-{1..3} have 9 veth* interfaces in ip addr show while na-arc-{1..5} don't have any veth* interfaces?
- Each container creates a veth* interface.
- Why does na-arc-3 have such poor network performance to the other na-arc nodes?
- ping na-arc-[1,2,4,5] with anything larger than -s 1490 drops all packets
- iperf tests show 10Gb/s between the VM host of na-arc-3 (naasc-vs-3 p5p1.120) and the VM host of na-arc-5 (naasc-vs-5 p2p1.120). So it isn't a bad card in either of the VM hosts.
- iptables on na-arc-3 looks different than iptables on na-arc-[2,3,5]. na-arc-1 also looks a bit different.
- docker_gwbridge interface on na-arc-[1,2,4,5] shows NO_CARRIER but not on na-arc-3.
- na-arc-3 has a veth10fd1da@if37 interface. None of the other na-arc-* nodes have a veth interface.
Production docker swarm iperf tests measured in Gb/s.
na-arc-1
(naasc-vs-4)
na-arc-2
(naasc-vs-4)
na-arc-3
(naasc-vs-3)
na-arc-4
(naasc-vs-4)
na-arc-5
(naasc-vs-5)
na-arc-1 18 0.002 20 10 na-arc-2
20 0.002 20 10 na-arc-3 0.002 0.002 0.002 0.002 na-arc-4 20 19 0.002 na-arc-5 10 10 0.002 10 10 There is clearly something wrong with na-arc-3
- ANSWER: Since there were so many problems with na-arc-3, it was decided to recreate it. It was recreated from a clone of na-arc-2.
- Is putting all the 1Gb/s production docker swarm nodes on the same ASIC on the same Fabric Extender of the cv-nexus switch a good idea?
- I am thinking it does not matter because it looks like the production docker swarm nodes use the 10Gb/s network which is on cv-nexus9k
- Can we set up a test archive query that uses the "other" docker swarm which in this case would be the production swarm (na-arc-*)?
- Why are there VLANs on the VM hosts. e.g. em1.97 on naasc-vs-4?
2022-08-12 dhart: If you want all of your guest VMs to be on the same subnet as the VM host, then VLAN awareness isn't needed. However, in most cases we want the flexibility of being able to have VM guests on different networks (from one another and/or the VM host) so the VM host is configured with a trunk interface to the network to allow for any VLAN to be passed to the underlying VM guests housed on that VM host machine
- 2022-08-12 dhart: 10.2.97.x (and 10.2.96.x) = internal VLAN for servers (primarily) 10.2.99.x = internal VLAN for server management
- 10.2.120.x = internal VLAN for 10 GE connections
- Where is the main docker config (yaml file)?
Conclusions
Adding a sixth node (na-arc-6) on a new VM Host (naasc-vs-2) showed the limiting factor in the table of iperf3 tests was not a node but a VM Host, specificly naasc-vs-4.
...
na-arc-1
(naasc-vs-4)
...
na-arc-2
(naasc-vs-4)
...
na-arc-3
(naasc-vs-3)
...
na-arc-4
(naasc-vs-4)
...
na-arc-5
(naasc-vs-5)
...
na-arc-6
(naasc-vs-2)
...
That allowed me to narrow my focus to just that host and the many differences it has from the other VM Hosts.
- 2022-09-02 krowe: sysctl -a | grep <10Gb NIC> between naasc-vs-3/naasc-vs-5 and naasc-vs-4 are different
- naasc-vs-4 has entries for VLANs 101 and 140 while naasc-vs-3 and naasc-vs-5 have entries for VLANs 192 and 96.
- 2022-09-02 krowe: sysctl -a on naasc-vs-4 and naasc-vs-5 and found many questionable differences
- naasc-vs-4: net.iw_cm.default_backlog = 256
- Is this because the IB modules are loaded?
- naasc-vs-4: net.rdma_ucm.max_backlog = 1024
- Is this because the IB modules are loaded?
- naasc-vs-4: sunrpc.rdma*
- Is this because the IB modules are loaded?
- naasc-vs-4: net.netfilter.nf_log.2 = nfnetlink_log
- nfnetlink is a module for packet mangling. Could this interfere with the docker swarm networking?
- naasc-vs-4: net.iw_cm.default_backlog = 256
- 2022-09-06 krowe: ethtool -k <NIC> for naasc-vs-3/naasc-vs-5 are very different from naasc-vs-4.
- hw-tc-offload: off vs hw-tc-offload: on
- rx-gro-hw: off vs rx-gro-hw: on
- rx-vlan-offload: off vs rx-vlan-offload: on
- rx-vlan-stag-hw-parse: off vs rx-vlan-stag-hw-parse: on
- tcp-segmentation-offload: off vs tcp-segmentation-offload: on
- tx-gre-csum-segmentation: off vs tx-gre-csum-segmentation: on
- tx-gre-segmentation: off vs tx-gre-segmentation: on
- tx-gso-partial: off vs x-gso-partial: on
- tx-ipip-segmentation: off vs tx-ipip-segmentation: on
- tx-sit-segmentation: off vs tx-sit-segmentation: on
- tx-tcp-segmentation: off vs tx-tcp-segmentation: on
- tx-udp_tnl-csum-segmentation: off vs tx-udp_tnl-csum-segmentation: on
- tx-udp_tnl-segmentation: off vs tx-udp_tnl-segmentation: on
- tx-vlan-offload: off vs tx-vlan-offload: on
- tx-vlan-stag-hw-insert: off vs tx-vlan-stag-hw-insert: on
- 2022-09-15 krowe: The VM Hosts have different 10Gb network cards
- naasc-vs-2 uses a Solarflare Communications SFC9220
- naasc-vs-3 uses a Solarflare Communications SFC9020
- naasc-vs-4 uses a Broadcom BCM57412 NetXtreme-E
- naasc-vs-5 uses a Solarflare Communications SFC9020
I see that rx-gro-hw is enabled on naasc-vs-4 but disabled on naasc-vs-2, 3, and 5. You can see this with ethtool -k em1 | grep gro. I found articles suggesting that GRO can make traffic slower when it is enabled, especially when using vxlan which Docker Swarm uses.
- GRO = Generic Receive Offload. It is hardware on the physical NIC. GRO is an aggregation technique to coalesce several receive packets from a stream into a single large packet, thus saving CPU cycles as fewer packets need to be processed by the kernel.
- https://bugzilla.redhat.com/show_bug.cgi?id=1424076
- https://access.redhat.com/solutions/20278
- https://techdocs.broadcom.com/us/en/storage-and-ethernet-connectivity/ethernet-nic-controllers/bcm957xxx/adapters/Tuning/tcp-performance-tuning/nic-tuning_22/gro-generic-receive-offload.html
- https://techdocs.broadcom.com/us/en/storage-and-ethernet-connectivity/ethernet-nic-controllers/bcm957xxx/adapters/Tuning/ip-forwarding-tunings/nic-tuning_48.html
- https://techdocs.broadcom.com/us/en/storage-and-ethernet-connectivity/ethernet-nic-controllers/bcm957xxx/adapters/Tuning/tcp-performance-tuning/os-tuning-linux.html
So I disabled it on naasc-vs-4 with ethtool -K em1 gro off and iperf3 tests now show about 2Gb/s both directions!!!
...
na-arc-1
(naasc-vs-4)
...
na-arc-2
(naasc-vs-4)
...
na-arc-3
(naasc-vs-3)
...
na-arc-4
(naasc-vs-4)
...
na-arc-5
(naasc-vs-5)
...
na-arc-6
(naasc-vs-2)
...
4460
...
4060
...
2710
...
2580
...
1090
...
4010
...
3380
...
NAASC Archive Stabilization Solutions