From the Use Case document (March 7, 2023) it appears that the Field Source parameters need to depend on the Capability. For example, the Pulsar Use Case notes "The user may optionally specify an estimate of the mean flux density, period, duty cycle, or dispersion measure; otherwise these would take on default or null values." So ideally the Field Source parameters would be a function of Capability and so the file import format would vary. We would therefore want this to be configurable via Solicitations.
N.B., Upon discussion we had already concluded that Field Sources had to be a function of Capacity and need to be configurable.. See the Algorithms document for a path forward on how this will work.